Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Front Med (Lausanne) ; 11: 1363286, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38665295

RESUMO

Purpose: To compare different corneal keratometry readings (swept-source-OCT-assisted biometry and Scheimpflug imaging) with a novel software platform for calculation of toric intraocular lenses. Setting: Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany. Design: Retrospective, non-randomized, clinical trial. Methods: Twenty-three eyes undergoing toric intraocular lens implantation were included. Inclusion criteria were preoperative regular corneal astigmatism of at least 1.00 D, no previous refractive surgery, no ocular surface diseases and no maculopathies. Lens exchange was performed with CALLISTO eye (Zeiss). For each patient, the expected postoperative residual refraction was calculated depending on three different corneal parameters of two different devices: standard K-front (K) and total keratometry (TK) obtained by a swept-source-OCT-assisted biometry system (IOL Master 700, Zeiss) as well as total corneal refractive power (TCRP) obtained by a Scheimpflug device (Pentacam AXL, Oculus). Barrett's formula for toric intraocular lenses was used for all calculations within a novel software platform (EQ workplace, Zeiss FORUM®). Results were statistically compared with postoperative refraction calculated according to the Harris dioptric power matrix. Results: The standard K values (mean PE 0.02 D ± 0.45 D) and TK values (mean PE 0.09 D ± 0.43 D) of the IOL Master 700 reached similar results (p = 0.96). 78% of eyes in both K and TK groups achieved SE within ±0.5 D of attempted correction and all eyes (100%) were within ±1.0 D of attempted correction in both groups. By contrast, the prediction error in the IOL calculation using the TCRP of the Scheimpflug device was significantly greater (mean PE -0.56 D ± 0.49 D; p = 0.00 vs. standard K and p = 0.00 vs. TK) with adjusted refractive indices. Thirty-nine and Ninety-one percentage of eyes in the TCRP group achieved SE within ±0.5 D (p = 0.008 K vs. TCRP and p = 0.005 TK vs. TCRP) and ± 1.0 D (p = 0.14 vs. TCRP) of attempted correction, respectively. Conclusion: All three corneal parameters (standard K, TK, TCRP) performed well in calculating toric IOLs. The most accurate refractive outcomes in toric IOL implantation were achieved by IOL calculations based on swept-source-OCT-assisted biometry. The SS-OCT-based K-front and TK values achieve comparable results in the calculation of toric IOLs.

2.
Sci Rep ; 14(1): 5648, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38453996

RESUMO

Implantable collamer lens implantation (ICL) represents a safe and effective treatment for myopia and myopic astigmatism. To compare the outcomes of a bilateral one-stage same day approach to a two-stage approach, the databases of the University Eye Hospital Munich, Ludwig Maximilians-University and Smile Eyes Linz, Austria were screened for eyes that had undergone ICL implantation. Two-stage surgery was performed at an interval of 1 day (17 patients), 2 days (19 patients) and 1 week (2 patients). Variables analyzed were preoperative, 1-day and last follow-up uncorrected distance (UDVA) and corrected distance visual acuity (CDVA), manifest refraction, refractive spherical equivalent (SEQ), astigmatism, age, endothelial cell count (ECD), intraocular pressure (IOP) and ICL vaulting. In total, 178 eyes (100 eyes one-stage, 78 eyes two-stage) of 89 patients were included in this study. Mean follow-up was 1.1 ± 0.8 and 1.3 ± 0.5 years. Mean preoperative SEQ was - 7.9 ± 2.6 diopters (D) in the one-stage and - 8.0 ± 1.7 D in the two-stage group (p = 0.63) and improved to 0.00 ± 0.40 and - 0.20 ± 0.40 D at end of follow-up, showing slightly better stability in the one-stage group (p = 0.004). There was no difference in the efficacy (1.1 vs. 1.2, p = 0.06) and the safety index (1.2 vs. 1.2, p = 0.60) between the two groups. No eye (0%) in either group lost 2 lines or more of UDVA (p > 0.99). Refraction within ± 0.50 D and ± 1.00 D around target was achieved comparably often (89 vs. 86%, p = 0.65; 99 vs. 99%, p > 0.99). Endothelial cell loss was slightly higher in the two-stage group (1.3 vs. 4.3%). Vaulting at the final follow up was higher in the one-stage group (373.8 ± 205.4 µm vs. 260.3 ± 153.5 µm, p = 0.00007). There were no serious intraoperative complications in either group. In conclusion, this study demonstrates that both the one- and two-stage approaches are equally effective, predictable and safe. Regarding endothelial cell loss, vaulting and SEQ stability, the one-stage group showed slightly better outcomes, but these results are clinically questionable because they are so small. Larger studies are needed to quantitatively evaluate a potential benefit.


Assuntos
Astigmatismo , Lentes Intraoculares , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular , Acuidade Visual , Refração Ocular , Resultado do Tratamento , Astigmatismo/cirurgia , Seguimentos , Estudos Retrospectivos
3.
Curr Eye Res ; 49(3): 252-259, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38032001

RESUMO

PURPOSE: AI (artificial intelligence)-based methodologies have become established tools for researchers and physicians in the entire field of ophthalmology. However, the potential of AI to optimize the refractive outcome of keratorefractive surgery by means of machine learning (ML)-based nomograms has not been exhausted yet. In this study, we wanted to comprehensively compare state-of-the-art conventional nomograms for Small-Incision-Lenticule-Extraction (SMILE) with a novel ML-based nomogram regarding both their spherical and astigmatic predictability. METHODS: A total of 1,342 eyes were analyzed for creation of three different nomograms based on a linear model (LM), a generalized additive mixed model (GAMM) and an artificial-neuronal-network (ANN), respectively. A total of 16 patient- and treatment-related features were included. Each model was trained by 895 eyes and validated by the remaining 447 eyes. Predictability was assessed by the difference between attempted and achieved change in spherical equivalent (SE) and the difference between target induced astigmatism (TIA) and surgically induced astigmatism (SIA). The root mean squared error (RMSE) of each model was computed as a measure of overall model performance. RESULTS: The RMSE of LM, GAMM and ANN were 0.355, 0.348 and 0.367 for the prediction of SE and 0.279, 0.278 and 0.290 for the astigmatic correction, respectively. By applying the created models, the theoretical yield of eyes within ±0.50 D of SE from target refraction improved from 82 to 83% (LM), 84% (GAMM) and 83% (ANN), respectively. Astigmatic outcomes showed an improvement of eyes within ±0.50 D from TIA from 90 to 93% (LM), 93% (GAMM) and 92% (ANN), respectively. Subjective manifest refraction was the single most influential covariate in all models. CONCLUSION: Machine learning endorsed the validity of state-of-the-art linear and non-linear SMILE nomograms. However, improving the accuracy of subjective manifest refraction seems warranted for optimizing ±0.50 D SE predictability beyond an apparent methodological 90% limit.


Assuntos
Astigmatismo , Ferida Cirúrgica , Humanos , Nomogramas , Inteligência Artificial , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Refração Ocular , Testes Visuais
4.
Int J Ophthalmol ; 16(8): 1231-1236, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37602351

RESUMO

AIM: To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL. METHODS: In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D). A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes. The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA). RESULTS: Preoperative refractive astigmatism was 2.14±1.17 D, which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.67±0.44 D at three months and 0.75±0.25 D at six months; for all groups: P<0.0001 compared to baseline). BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery (P=0.02). Mean IOL axis deviation from the target axis was 3.4°±2.9° after six to eight weeks and significantly decreased over time (2.4°±2.6° six months after surgery; P=0.04). In one patient IOL, re-alignment was performed. CONCLUSION: Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery. The plate haptic toric IOL position and axis remain stable during the observation period of six months.

6.
Int J Mol Sci ; 24(5)2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36902019

RESUMO

The aim of this study was to evaluate the long-time results of highly concentrated autologous platelet-rich plasma (PRP) used as an adjunct in lamellar macular hole (LMH) surgery. Nineteen eyes of nineteen patients with progressive LMH were enrolled in this interventional case series, on which 23/25-gauge pars plana vitrectomy was performed and 0.1 mL of highly concentrated autologous platelet-rich plasma was applied under air tamponade. Posterior vitreous detachment was induced, and the peeling of tractive epiretinal membranes, whenever present, was performed. In cases of phakic lens status, combined surgery was carried out. Postoperatively, all patients were instructed to remain in a supine position for the first two postoperative hours. Best-corrected visual acuity (BCVA) testing, microperimetry, and spectral domain optical coherence tomography (SD-OCT) were carried out preoperatively and at minimum 6 months (in median 12 months) postoperatively. Foveal configuration was postoperatively restored in 19 of 19 patients. Two patients who had not undergone ILM peeling showed a recurring defect at 6-month follow-up. Best-corrected visual acuity improved significantly from 0.29 ± 0.08 to 0.14 ± 0.13 logMAR (p = 0.028, Wilcoxon signed-rank test). Microperimetry remained unchanged (23.38 ± 2.53 preoperatively; 23.0 ± 2.49 dB postoperatively; p = 0.67). No patients experienced vision loss after surgery, and no significant intra- or postoperative complications were observed. Using PRP as an adjunct in macular hole surgery significantly improves morphological and functional outcomes. Additionally, it might be an effective prophylaxis to further progression and also the formation of a secondary full-thickness macular hole. The results of this study might contribute to a paradigm shift in macular hole surgery towards early intervention.


Assuntos
Membrana Epirretiniana , Perfurações Retinianas , Humanos , Perfurações Retinianas/complicações , Perfurações Retinianas/cirurgia , Recidiva Local de Neoplasia/cirurgia , Fóvea Central , Membrana Epirretiniana/complicações , Membrana Epirretiniana/cirurgia , Vitrectomia/métodos , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos
8.
Curr Eye Res ; 48(4): 357-364, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36524538

RESUMO

PURPOSE: To compare the efficacy of digital-assisted reference marking for toric implantable collamer lenses (Callisto Eye System) with manual marking technique using a slit lamp markeur. METHODS: This study included patients that underwent implantation of a toric implantable collamer lens (EVO Visian toric ICL, Staar Surgical). Patients were included if they had a myopia above -3 diopters (D) and regular corneal astigmatism of 0.75 diopters or higher. Between both groups a 1:2 matching regarding similar preoperative level of myopia and astigmatism was performed. Visual and refractive outcomes were evaluated. Vector analysis was performed to evaluate total astigmatic changes. RESULTS: This study comprised 57 eyes of 57 patients with 19 eyes in the digital group and 38 eyes in the manual marking group. Postoperatively there were no statistically significant differences between both groups in UDVA (p = 0.467), spherical equivalent (SE) (p = 0.864), sphere (p = 0.761) and cylinder (p = 0.878). Vector analysis showed a slightly more accurate postoperative refractive astigmatism in the manual group (0.26 D at 107° ± 0.50 D) compared to the digital marking group (0.31 D at 107° ± 0.45 D), nevertheless with no statistically significant differences between both groups. CONCLUSIONS: A digital tracking approach for toric ICL alignment was an efficient and safe method for toric marking with similar results regarding visual and refractive outcomes compared to a conventional corneal marking method. Nevertheless, image-guided surgery helped to streamline the workflow in refractive ICL surgery.


Assuntos
Astigmatismo , Miopia , Humanos , Astigmatismo/cirurgia , Acuidade Visual , Implante de Lente Intraocular/métodos , Refração Ocular , Miopia/cirurgia , Resultado do Tratamento
9.
Klin Monbl Augenheilkd ; 239(11): 1354-1360, 2022 Nov.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-35790199

RESUMO

With an estimated incidence of 0.011%, the SMILE procedure seems to have the lowest risk of postoperative keratectasia among contemporary keratorefractive procedures. Nevertheless, due to the novelty of the procedure as well as the lack of data, no clear superiority over femto-LASIK or PRK can be stated at this time. In this respect, application of the identical tomographic screening criteria previously developed for excimer-based procedures is of paramount importance to minimize the risk of corneal ectasia. As an adjunct to conventional corneal tomography, newer imaging modalities such as OCT-based epithelial mapping should be used for preoperative screening before keratorefractive surgery. Corneal crosslinking is an established treatment modality for post-SMILE keratectasia, which promises high success rates especially in early stages. The present case report illustrates these diagnostic and therapeutic considerations.


Assuntos
Colágeno , Córnea , Doenças da Córnea , Miopia , Procedimentos Cirúrgicos Refrativos , Humanos , Colágeno/metabolismo , Córnea/diagnóstico por imagem , Córnea/metabolismo , Córnea/cirurgia , Doenças da Córnea/etiologia , Doenças da Córnea/metabolismo , Doenças da Córnea/terapia , Substância Própria/cirurgia , Dilatação Patológica , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/diagnóstico por imagem , Miopia/cirurgia , Procedimentos Cirúrgicos Refrativos/efeitos adversos , Procedimentos Cirúrgicos Refrativos/métodos
10.
J Refract Surg ; 38(5): 280-287, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35536709

RESUMO

PURPOSE: To evaluate postoperative subjective quality of vision in patients who underwent Implantable Collamer Lens (ICL) (STAAR Surgical) implantation for correction of myopia and to identify potential predictive parameters. METHODS: In this single-center cross-sectional study, a total of 162 eyes of 81 patients (58 women, 23 men) who underwent ICL implantation were analyzed. The Quality of Vision (QOV) questionnaire was used to assess patient-reported outcomes. Baseline characteristics (eg, age), treatment parameters (eg, surgical corrected refraction), and refractive (eg, residual refraction) and visual (eg, uncorrected distance visual acuity) outcomes were analyzed regarding their effect on QOV. RESULTS: Mean age was 33.3 ± 7.0 years (range: 21 to 51 years) and mean preoperative spherical equivalent was -8.42 ± 2.49 diopters (D) (range: -3.25 to -14.38 D). After a mean postoperative follow-up period of 19 ± 14 months (range: 6 to 54 months), the safety index score was 1.23 ± 0.21 and the efficacy index score was 1.17 ± 0.22. The mean QOV scores were 35.5 ± 11.3, 32.2 ± 11.1, and 23.3 ± 16.1 for frequency, severity, and bothersomeness, respectively. The most frequently experienced symptoms were halos (90.1%) and glare (66.7%). Halos appeared in 66.7% of the patients "occasionally" and 5 of them (6.2%) experienced them "very often." Only 1 patient (1.2%) classified halos as "very bothersome." Patients older than 36 years reported visual symptoms more frequently (P < .05) and showed higher bothersomeness scores (P = .01). CONCLUSIONS: Halos are the most commonly perceived long-term visual disturbance after myopic ICL implantation with a central hole. Visual symptoms can persist more than 6 months postoperatively, causing only minor disturbances in most cases. Older patients seem more prone to experiencing these symptoms. [J Refract Surg. 2022;38(5):280-287.].


Assuntos
Miopia , Lentes Intraoculares Fácicas , Adulto , Estudos Transversais , Feminino , Seguimentos , Humanos , Implante de Lente Intraocular , Masculino , Miopia/cirurgia , Refração Ocular , Resultado do Tratamento
11.
Ophthalmologie ; 119(10): 1041-1046, 2022 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-35499634

RESUMO

BACKGROUND: Phototherapeutic keratectomy (PTK) is an established treatment method for patients suffering from either genetic corneal dystrophy or recurrent corneal erosion (RCE) without underlying basement membrane dystrophy, often caused by trauma. OBJECTIVE: This study aimed to describe the changes in manifest subjective refraction and pachymetry after PTK treatment in patients suffering from epithelial basement membrane dystrophy (EBMD) and traumatic or atraumatic RCE without underlying EBMD. MATERIAL AND METHODS: This was a retrospective, single-center study performed at the Department of Ophthalmology of the Ludwig-Maximilians University (Munich). Patient data were retrospective collected using the smart-eye database of the Department of Ophthalmology including diagnostic data from an autorefractometer and from the Pentacam HR. All laser treatments were performed with an ablation depth of 10 µm for EBMD patients and 6 µm for RCE patients without EBMD. RESULTS: Both collectives showed a decrease in pachymetry larger than the calculated ablation depths after a follow-up interval of 126 days (95% CI 104-147 days). While the EBMD collective receiving an ablation of 10 µm showed a decrease of 25.8 µm (N = 74; 95% CI 21.2-30.3; p < 0.001), the non-EBMD collective receiving an ablation of 6 µm showed a decrease of 12.3 µm (N = 44, 95% CI 7.0-17.7; p < 0.001). Both, total corneal refractive power (TCRP) as well as spherical equivalent (SE) offered no significant change in preoperative and postoperative comparison for the EBMD collective. On the other hand, patients without underlying EBMD showed a significant myopic decrease in SE of 0.4 dpt (±0.7 dpt SD, p < 0.05). The mean follow-up interval was 126 days (95% CI 104-147 days). CONCLUSION: PTK treatment offers an effective method for patients suffering from either EBMD dystrophy or RCE syndrome without underlying EBMD. The final ablation based on pachymetry at the apex can be estimated at 2.3 to 2.6 times higher compared to the original ablation depth. The reasons for this are on the one hand the laser ablation itself and the influence of the reactive wound healing of the corneal epithelium.


Assuntos
Distrofias Hereditárias da Córnea , Úlcera da Córnea , Ceratectomia Fotorrefrativa , Distrofias Hereditárias da Córnea/cirurgia , Úlcera da Córnea/complicações , Humanos , Ceratectomia/efeitos adversos , Lasers de Excimer/uso terapêutico , Ceratectomia Fotorrefrativa/efeitos adversos , Estudos Retrospectivos , Acuidade Visual
12.
J Clin Med ; 11(10)2022 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35629035

RESUMO

Background: To determine whether there is a significant saving of time when using a digital cataract workflow for digital data transfer compared to a manual approach of biometry assessment, data export, intraocular lens calculation, and surgery time. Methods: In total, 48 eyes of 24 patients were divided into two groups: 24 eyes were evaluated using a manual approach, whereas another 24 eyes underwent a full digital lens surgery workflow. The primary variables for comparison between both groups were the overall time as well as several time steps starting at optical biometry acquisition until the end of the surgical lens implantation. Other outcomes, such as toric intraocular lens misalignment, reduction of cylinder, surgically induced astigmatism, prediction error, and distance visual acuity were measured. Results: Overall, the total diagnostic and surgical time was reduced from 1364.1 ± 202.6 s in the manual group to 1125.8 ± 183.2 s in the digital group (p < 0.001). The complete time of surgery declined from 756.5 ± 82.3 s to 667.3 ± 56.3 (p < 0.0005). Compared to the manual approach of biometric data export and intraocular lens calculation (76.7 ± 12.3 s) as well as the manual export of the reference image to a portable external storage device (26.8 ± 5.5 s), a highly significant saving of time was achieved (p < 0.0001). Conclusions: Using a software-based digital approach to toric intraocular lens implantation is convenient, more efficient, and thus more economical than a manual workflow in surgery practice.

13.
Curr Eye Res ; 47(1): 12-17, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34369205

RESUMO

PURPOSE: To evaluate the value of total keratometry (TK) to estimate corneal power in eyes that underwent SMILE for treatment of myopia or myopic astigmatism in subgroups of low and high astigmatism. METHODS: The difference between preoperative and postoperative measurements of corneal power (ΔTCRP, ΔTK) was compared with the surgically induced refractive change at the corneal plane (ΔSEco) by Pearson correlation. Vector analysis of TCRP- and TK-derived astigmatism was performed to evaluate the corneal astigmatism. Single-angle plots were generated with the AstigMATIC tool for standard astigmatism vector analysis. RESULTS: Paired t-test revealed statistically significant differences in preoperative (p = .02) and postoperative (p = .0455) measurements between TK and TCRP in the group of high-level astigmatism and the postoperative low astigmatism group (p < .01). No significant differences were found in preoperative data in the group of low-level astigmatism (p = .60). The correlation of ΔSEco and TK (low astigmatism, R2 = 0.978; high astigmatism R2 = 0.980) was stronger than the correlation of TCRP 4.0 mm and ΔSEco (low astigmatism, R2 = 0.743; high astigmatism R2 = 0.959) in both astigmatic groups. The vector analysis demonstrated nearly identical results concerning the correction index (CI) for TK and TCRP. Comparing the difference vector (DV) between both parameters, TK-derived results were closer to the optimum. CONCLUSIONS: The findings endorse TK as a reliable measure of corneal power after SMILE in patients with low and high astigmatism.


Assuntos
Astigmatismo/cirurgia , Córnea/diagnóstico por imagem , Cirurgia da Córnea a Laser/métodos , Miopia/cirurgia , Refração Ocular/fisiologia , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Adulto , Astigmatismo/diagnóstico , Astigmatismo/fisiopatologia , Córnea/cirurgia , Topografia da Córnea/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico , Miopia/fisiopatologia , Período Pós-Operatório , Estudos Prospectivos , Adulto Jovem
14.
J Cataract Refract Surg ; 48(1): 89-94, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34091552

RESUMO

PURPOSE: To analyze precision and safety of femtosecond laser-assisted descemetorhexis and postoperative corneal wound healing in human ex vivo specimens. SETTING: Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany. DESIGN: Experimental ex vivo study. METHODS: 4 donor corneas underwent femtosecond laser-assisted descemetorhexis. The descemetorhexis was performed using the LDV Z8 femtosecond laser, followed by live/dead staining, phase contrast microscopy, and scanning electron microscopy. The descemetorhexis parameters were set using a modified optical coherence tomography image capturing of 8 segments within a focus of 100 µm at the posterior corneal stroma (reversed capsulotomy program). RESULTS: Live/dead sample staining analysis demonstrated that the femtosecond laser had minimal impact on the vitality of surrounding endothelial cells. Phase contrast microscopy and scanning electron microscopy evaluation showed that the laser produced precise, clear-cut edges, leaving no stromal tissue bridges. CONCLUSIONS: Femtosecond laser-assisted descemetorhexis could serve as a safe and precise technique with only minimal endothelial cell damage. To minimize stromal damage, further laser energy profile adjustments are necessary to optimize corneal treatment within different stages of corneal tissue swelling.


Assuntos
Transplante de Córnea , Lâmina Limitante Posterior , Lâmina Limitante Posterior/cirurgia , Células Endoteliais , Endotélio Corneano , Humanos , Lasers
16.
Sci Rep ; 11(1): 24427, 2021 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-34952916

RESUMO

Studying anterior lens capsule cutting edge profiles from femtosecond laser-assisted capsulotomy procedures performed before and after lens fragmentation. Twenty eyes (10 patients) with age-related cataract underwent femtosecond laser-assisted surgery (FLACS) using the Ziemer Z8 platform. First step of laser surgery was either capsulotomy (group first) or fragmentation (group second). One eye of each patient was assigned randomly, the second eye treated with the different sequence of procedures. After anterior capsule removal, tissue was fixed in cacodylate-buffered solution and cutting-edge profiles were analysed using scanning electron microscopy (SEM). All cases had cataract grade 2 and 3 based on LOCS III grading. SEM analysis showed more smooth edges in the first group, especially in cases with pseudoexfoliation (P = 0.037); more tags and bridges and a significant number of staggered cutting patterns (7 out of 10 cases) in the second group. All cases evolved the same microgroves with "valleys and mountains " as signs of the photodisruption process. Femtosecond laser capsulotomy should be performed before lens fragmentation minimizing the rate of cutting errors. Especially in eyes with advanced cataract, as intracapsular pressure may increase due to lens fragmentation without anterior capsular opening.


Assuntos
Cápsula Anterior do Cristalino/ultraestrutura , Extração de Catarata/métodos , Catarata , Terapia a Laser/métodos , Cristalino/ultraestrutura , Idoso , Idoso de 80 Anos ou mais , Catarata/diagnóstico por imagem , Catarata/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
Klin Monbl Augenheilkd ; 238(11): 1213-1219, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34528231

RESUMO

PURPOSE: To evaluate the reliability of spectral-domain optical coherence tomography (SD-OCT; RTVue XR; Optovue, Inc., Fremont, CA, USA) for thickness mapping of the entire cornea (CT), corneal epithelium (ET). and corneal stroma (ST) over a 9-mm zone in healthy eyes. We sought to develop reference values for different age groups and elucidate potential sex- and age-dependent characteristics of corneal sublayer pachymetry maps. METHODS: Three consecutive SD-OCT scans were obtained in 166 healthy right eyes (mean age = 50 ± 20 years). The thickness maps contain 25 sectors over a 9-mm diameter zone. To test measurement reliability, intraclass correlation coefficients (ICC), coefficients of variation (CoV), and within-subject standard deviations (WSSD) were calculated. RESULTS: CT, ET, and ST ICCs ranged from 0.961 to 0.998, 0.896 to 0.945, and 0.955 to 0.998, respectively. CoV values for CT, ET, and ST ranged between 0.3 and 1.5%, 1.6 and 4.2%, and 0.4 and 1.7%, respectively. WSSD ranged from 6 to 41, 4 to 8, and 7 to 46 µm, respectively. A negative correlation was found between age and ET (p < 0.05) but not between age and ST or CT. No gender-related differences in CT, ET, or ST were detected. CoV of CT, ET, and ST measurements showed a positive correlation with age in 28, 64, and 28% of the sectors, respectively. CONCLUSION: SD-OCT is a rapid and noninvasive technique that provides excellent reliability for corneal sublayer thickness measurements over a 9-mm zone. The reliability of the ET measurement seems to be negatively affected by age. Peripheral CT and global ET thin with age.


Assuntos
Epitélio Corneano , Tomografia de Coerência Óptica , Adulto , Idoso , Córnea , Paquimetria Corneana , Epitélio Corneano/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
18.
Klin Monbl Augenheilkd ; 238(11): 1220-1228, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34528232

RESUMO

PURPOSE: To determine the effect of lockdown on medical care, with the example of ophthalmology. METHODS: Patients in a period during the first lockdown were compared to a non-lockdown period, with a total of 12 259 patients included in an observational study. Changes in different areas (elective, emergency, inpatients, surgeries) and eye care subspecialties were compared. Emergency patients were analyzed according to severity and urgency. Patients showing hints requiring treatment for urgent cardiovascular diseases were determined. Differences in patients who would have suffered severe vision loss without treatment were identified and the QALY (quality-adjusted life years) loss was determined accordingly. A model to prioritize patient visits after the end of lockdown or in future lockdown scenarios was developed. Data were collected at the University Eye Hospital LMU Munich and patient files were reviewed individually by ophthalmologists. RESULTS: The average patient number decreased by - 59.4% (p < 0.001), with a significant loss in all areas (elective, emergency, inpatients, surgeries; p < 0.001). There was a decline of - 39.6% for patients at high risk/high severity. Patients with indications of a risk factor of future stroke declined significantly (p = 0.003). QALY loss at the university eye hospital was 171, which was estimated to be 3160 - 24 143 for all of Germany. Working up high losses of outpatients during these 8 weeks of projected lockdown in Germany would take 7 - 23 weeks under normal circumstances, depending on ophthalmologist density. The prioritization model can reduce morbidity by up to 78%. CONCLUSION: There was marked loss of emergency cases and patients with chronic diseases. Making up for the losses in examinations and treatments will theoretically take weeks to months. To reduce the risk of morbidity, we recommend a prioritization model for rescheduling and future lockdown scenarios.


Assuntos
COVID-19 , Oftalmologia , Controle de Doenças Transmissíveis , Humanos , Assistência ao Paciente , Estudos Retrospectivos , SARS-CoV-2
19.
Sci Rep ; 11(1): 17854, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-34497302

RESUMO

Little is known about the connection between preoperative keratometry and postoperative results of myopic small-incision lenticule extraction (SMILE). To determine the influence of extreme (flat and steep) corneal keratometry on the safety and efficacy of SMILE, the databases of the Department of Ophthalmology, Ludwig-Maximilians-University Munich, Germany, and SMILE Eyes Linz, Austria, were screened for patients with steep and flat keratometry who had undergone SMILE. In this cross-sectional matched comparative cohort study, eyes with markedly flat (< 42.0 diopters; D) or steep (≥ 47.0D) preoperative corneal keratometry were matched to a cohort of eyes with regular keratometry (42.0-46.9D) by preoperative manifest refractive spherical equivalent and cylinder, age, corrected distance visual acuity and surgical SMILE parameters. The standardized graphs and terms for refractive surgery results were applied to compare the three groups. Changes in higher order aberrations (HOAs) were evaluated on Scheimpflug imaging. In total, 63 eyes (21 each) of 54 patients with a mean refractive spherical equivalent of - 5.21 ± 1.59 D were followed up for a mean of 9.2 ± 6.1 (minimum ≥ 3) months. Mean baseline keratometry was 41.3 ± 0.7D (flat), 45.5 ± 1.0D (regular) and 47.7 ± 0.6D (steep) (p < 0.0001). Compared to the regular group, the flat and the steep cornea group resulted in a non-inferior percentage of eyes within ± 0.50 D of target refraction (p = 0.20), uncorrected distance visual acuity (p = 0.95) and corrected distance visual acuity (p = 0.20). Flat corneas however experienced a stronger induction of spherical aberration (SA) compared to the steep group (p = 0.0005). In conclusion, non-inferior outcomes of SMILE can also be expected in eyes with steep (≥ 47D) or flat (< 42D) preoperative keratometry, while SMILE however induces more SA in eyes with a flat keratometry.


Assuntos
Astigmatismo/cirurgia , Córnea/cirurgia , Miopia/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Adulto , Feminino , Humanos , Masculino , Microcirurgia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...